UL Standards
Underwriters
Laboratories (UL) is one of the leading developers of product safety standards
which manufacturers use in designing and producing safe products. All of UL's
Standards for Safety are compatible with the U.S. National Electric
Code and other nationally recognized installation, building and safety
codes. Over 800 Standards for Safety have been published by UL.
UL 583, UL 1203 and UL 1604 are the Standards for Safety that contain
the technical requirements that EX trucks must meet to become eligible
to be labeled as Explosion Proof. It is not sufficient to say that
products are built to these UL standards. Only products tested by UL
that meet these standards are eligible to bear the
UL Mark.
All UL labeled Gregory
EX Trucks have been tested and Classified by UL and meet or exceed UL
583, UL 1203 and UL 1604 Standards for Safety. In addition, as a UL Classified Type
EX truck, Gregory EX Trucks have all utilized electrical components separately tested
and approved prior to testing the entire forklift electrical system for EX
integrity.
UL 583 - Electric-Battery-Powered
Industrial Trucks
View
the UL 583 summary from the UL Website
A Type EX
truck must meet the fire and shock hazard requirements of UL 583. UL performs a
series of tests for UL 583 Classification Testing which include:
abnormal operation test, electrical component temperatures test, brake test,
dielectric voltage withstand test, arc-rupture tests on motor controllers and
switching contacts in all circuits, burnout test, and solid-state circuitry
component malfunction analysis.
UL 1203 - Explosive-Proof and Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified)
Locations
View
the UL 1203 summary from the UL Website
A Type EX truck used in
Division 1 Hazardous Locations must meet UL 1203 requirements.
Explosion Proof enclosures for Class I, Division 1 trucks are
subjected by UL to explosion and hydrostatic pressure withstand test during
UL 1203 Classification Testing.
UL also performs
dust penetration and dust blanket temperature tests for dust-ignition-proof enclosures
for Class II, Division 1 trucks.
UL 1604 - Electric
Equipment for Use in Class I and Class II,
Division 2, and Class III Hazardous (Classified)
Locations
View
the UL 1604 summary from
the UL Website
A Type EX truck used in Class I,
Division 2 Hazardous Locations must meet UL 1604 requirements. During UL 1604
Classification Testing,
UL conducts a spark ignition
test, nonincendive components tests, dust-tight-enclosure tests and sealed
device tests.
|
|